    Low voltage switchgear kit

    Model:GGD type AC Low-voltage Power Distribution Cabinets

    Application:

    GGD AC low-voltage distribution cabinet is suitable for power users such as power plants, substations, factories and mines, etc., with AC 50Hz, rated working voltage of 380V and rated working current of 3150AA. It is used for power conversion, distribution and control of power, lighting and distribution equipment.

    GGD AC low-voltage distribution cabinet is a new type of low-voltage distribution cabinet designed according to the requirements of the competent superiors of the Ministry of Energy, the majority of power users and design departments, and based on the principles of safety, economy, rationality and reliability. The product has the characteristics of high breaking capacity, good dynamic and thermal stability, flexible electrical scheme, convenient combination, series, strong practicability, novel structure and high protection level, and can be used as an updated product of low-voltage switch gear. GGD AC low-voltage distribution cabinet meets IEC439 Low-voltage switch gear and control gear, GB7251 Low-voltage switch gear and other standards.

    Features:

    1. The ambient air temperature is not higher than+40℃,not lower than-5℃,the average temperature within 24h shall not be higher than+ 35℃;

    2. Indoor installation and use,the altitude of the place of use shall not exceed 2000m;

    3. The relative humidity of the surrounding air does not exceed 50%at the maximum temperature of +40℃.It should low a large relative humidity at a lower temperature (for  example,90%at+20℃).Considering that the temperature may change accidentally   Produce the effects of condensation;

    4. The inclination of the equipment when installed is not more than 5°with the vertical plane;

    5. The equipment should be installed in places where there is no severe vibration and shock,and where it is not enough to corrode electrical components;

    6. Users can negotiate with the manufacturer if they have special requirements.

    Specification:

    Model

    Rated voltage

    (V)

    Rated current

    (A)

    Rated short-circuit

    breaking current

    (kA)

    Rated short-time

    withstand current

    (1s)(kA)

    Rated peak withstand

    current

    (kA)

    GGD1

    380

    A

    1000

    15

    15

    30

    GGD1

    380

    B

    600(630)

    15

    15

    30

    GGD1

    380

    C

    400

    15

    15

    30

    GGD2

    380

    A

    1500(1600)

    30

    30

    63

    GGD2

    380

    B

    1000

    30

    30

    63

    GGD2

    380

    C

    600

    30

    30

    63

    GGD3

    380

    A

    4000

    50

    50

    105

    GGD3

    380

    B

    2500

    50

    50

    105

    GGD3

    380

    C

    2000

    50

    50

    105